Traditional Build

  • Use KORE Floor Solution for Solid Ground Floors
  • Use KORE Pack Solution for Flat Ceilings
  • Use KORE Fill Solution for Full Fill Cavity Walls or use KORE Key Solution for Partial Fill Cavity Walls
  • Use KORE Lock Solution for both Warm Pitched Roofs and Cold Pitched Roofs

 

Find the best KORE solution for you*

(select an Energy  Rating)

Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.12 200mm Silver
Full Fill Cavity Wall KORE Fill + KORE Linear Drylining 0.12 200mm Silver + 40mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.12 160mm Silver + 65mm Silver
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.12 250mm Silver + 40mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.12 265mm Silver + 35mm Silver
Flat Ceiling KORE Pack 0.12 300mm White
Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.12 200mm Silver
Full Fill Cavity Wall KORE Fill 0.15 200mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.15 150mm Silver + 40mm White
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.12 250mm Silver + 40mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.12 265mm Silver + 35mm Silver
Flat Ceiling KORE Pack 0.12 300mm White
Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.16 150mm Silver
Full Fill Cavity Wall KORE Fill 0.20 150mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.20 100mm Silver + 40mm White
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.14 200mm Silver + 40mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.14 210mm Silver + 35mm Silver
Flat Ceiling KORE Pack 0.14 260mm White
Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.18 125mm Silver
Full Fill Cavity Wall KORE Fill 0.22 135mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.22 85mm Silver + 40mm White
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.16 180mm Silver + 25mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.16 190mm Silver + 25mm Silver
Flat Ceiling KORE Pack 0.14 260mm White
Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.22 115mm White
Full Fill Cavity Wall KORE Fill 0.25 120mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.25 70mm Silver + 40mm White
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.20 115mm Silver + 25mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.20 125mm Silver + 25mm Silver
Flat Ceiling KORE Pack 0.16 225mm White
Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.25 100mm White
Full Fill Cavity Wall KORE Fill 0.27 110mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.27 65mm Silver + 35mm White
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.20 115mm Silver + 25mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.20 125mm Silver + 25mm Silver
Flat Ceiling KORE Pack 0.16 225mm White
Product Solution U-Value Type
Solid Ground Floor KORE Floor 0.25 100mm White
Full Fill Cavity Wall KORE Fill 0.27 110mm Silver
Partial Fill Cavity Wall KORE Key + KORE Linear Drylining 0.27 65mm Silver + 35mm White
Warm Pitched Roof KORE Lock + KORE Linear Drylining 0.20 115mm Silver + 25mm Silver
Cold Pitched Roof KORE Lock + KORE Linear Drylining 0.20 125mm Silver + 25mm Silver
Flat Ceiling KORE Pack 0.16 225mm White



Additional Specifications**

  A Grade B Grade C Grade
Glazing (W/m²K) 0.8 - 1.3 1.8 - 2.2 2.6
Airtightness (m³/hr/m²) 2 5 Default Not Tested
Lighting (CFL) 100% 100% 30%
Space Heating 98% Oil 95% Oil 85% Oil
Water Heating 4m² Solar Panels Heating System Heating System
Ventilation Heat Recovery 95% Natural Natural
Photovoltic 5m² None None

 

 

*The thickness of insulating material required to achieve a given U-Value can vary depending on the grade of material used and the exact application conditions. For different thickness options and advice please contact our technical department. Floor P/A taken as 0.5.

** The details above are designed as a guide. They are an indication of the U-Values required to meet Building Energy Ratings. Given that the elements of every dwelling will vary the above information is subject to change. It is vital that a fully qualified BER assessor undertakes the BER assessment to determine every individual dwelling requirement.