Concrete Specification
|
Strength
|
25 Newton
|
|
Slump
|
Max 150mm
|
|
Aggregate – 150mm Concrete Core
|
10-13mm
|
|
Aggregate – 200mm Concrete Core
|
10-19mm
|
KORE Concrete Volume
|
Concrete Thickness
|
Concrete Volume m³ per m² Wall
|
|
150mm
|
0.150
|
|
200mm
|
0.200
|
|
300mm
|
0.300
|
Concrete Placement
|
Placement Method
|
Application
|
Advantages
|
|
Concrete Pump
|
Directly from discharge point into KORE Formwork
|
Different Pumps Reaches Continuous Concrete Stream Pump moves vertically & horizontally High mobility and versatility
|
|
Crane & Skip
|
Used to place concrete from discharge point into KORE Formwork
|
Clean discharge Various skip capacities available Cranes have other uses on site
|
|
Hand
|
Directly from discharge point into KORE Formwork
|
Make up deficiencies at end of pour Fill voids at cill area
|
KORE ICF U-value (W/m²K) Table
|
External Finish
|
Concrete Thickness (mm)
|
Concrete Strength (N)
|
U-value (W/m²K)
|
|
Render
|
150
|
25
|
0.20
|
|
Render
|
200
|
25
|
0.19
|
|
Render
|
150
|
30
|
0.20
|
|
Render
|
200
|
30
|
0.20
|
|
Brick
|
150
|
25
|
0.19
|
|
Brick
|
200
|
25
|
0.19
|
|
Brick
|
150
|
30
|
0.19
|
|
Brick
|
200
|
30
|
0.19
|
Note: KOREFill λ = 0.033W/mK
|