For Attics at Ceiling Level install Climowool and KORE Loft insulation between and over the joists. For Pitched Roofs access between rafters and install KORE Lock or Climowool and apply KORE Linear Drylining to studded walls and sloping ceilings.
For Cavity Walls install KORE Fill and for Cavity Blocks install KORE Linear Drylining.
Insulating floors in existing buildings is very costly and disruptive. It is advised to undertake this work if work on the floor needs to be done anyway.
A few other tips for insulating existing homes are:
| Year House Build | Cavity Width | Expected Insulation Level in Cavity | U-Value | Installed | New U-Value |
| 1997–2002 |
100mm |
60mm SD EPS |
0.45 |
40mm |
0.29 |
| 1990–1997 |
100mm |
50mm SD EPS |
0.51 |
50mm |
0.29 |
| 1980’s |
80mm |
40mm SD EPS |
0.59 |
40mm |
0.35 |
| 1970’s |
40mm |
None |
1.65 |
40mm |
0.55 |
| Year House Build | Cavity Width | Expected Insulation Level in Cavity | U-Value | Installed | New U-Value |
| 1997–2002 |
100mm |
60mm SD EPS |
0.45 |
50mm |
0.27 |
| 1990–1997 |
100mm |
50mm SD EPS |
0.51 |
60mm |
0.27 |
| 1980’s |
80mm |
40mm SD EPS |
0.59 |
70mm |
0.27 |
| 1970’s |
40mm |
None |
1.65 |
105mm |
0.27 |
Expected Results with KORE Pack Attic Insulation***
| Year House Built | Expected Insulation Level in Attic | U-Value | Installed | New U-Value |
| 1997–2002 |
150mm |
0.24 |
100mm |
0.16 |
| 1990–1997 |
100mm |
0.35 |
125mm |
0.16 |
| 1980’s |
50mm |
0.42 |
170mm |
0.16 |
| 1970’s |
None |
2.55 |
225mm |
0.16 |
* Insulation = 0.033W/mK